Home-automation OmniPro II Manual de usuario

Busca en linea o descarga Manual de usuario para La Seguridad Home-automation OmniPro II. Home Automation OmniPro II User Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 100
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
HOME AUTOMATION, INC.
Control & Security System
Owner's Manual
Document Number 20R00-2 Rev. 2.11
January, 2006
Vista de pagina 0
1 2 3 4 5 6 ... 99 100

Indice de contenidos

Pagina 1 - Owner's Manual

HOME AUTOMATION, INC. Control & Security System Owner's Manual Document Number 20R00-2 R

Pagina 2 - All Rights Reserved

OVERALL DESCRIPTION Console Operation The console is designed with everything that is necessary for you to program and operate your OmniPro II contr

Pagina 3 - Contents

NOTE TO INSTALLER Following installation, this manual shall be left for the homeowner's use. HAI •

Pagina 4

6- UP ARROW The Up Arrow key is used to scroll through menus and lists. The Up Arrow is used to scroll back through a list (for example, if you have

Pagina 5

When using the arrow keys to scroll through lists of areas, buttons, codes, temperature zones, units, or zones, only the named items are displayed. I

Pagina 6

Confirmation Beep When you have successfully completed a function, such as entering a program or changing a setup item, the console will beep once.

Pagina 7

SECURITY SYSTEM OPERATION Disarming the Security System and Silencing Alarms Before going any further, you should know how to disarm your security

Pagina 8

2 = NIGHT The NIGHT mode is used when you are asleep and everyone in your household is at home. In the Night mode, your doors, windows, and non-slee

Pagina 9 - INTRODUCTION

Quick Arm For extra convenience, the OmniPro II can be armed by simply pressing the DAY, NIGHT, or AWAY button twice, eliminating the need to enter t

Pagina 10 - OVERALL DESCRIPTION

#=GOTO To Bypass or Restore a zone in another area, you must first "go to" that area by selecting #=GOTO. AREA: ENTER AREA: At th

Pagina 11 - Display Menus

For more information on the digital and voice dialer - See Digital Dialer and Voice Dialer. • The system continues to sound all alarms and flash the

Pagina 12

Police Emergency When the 1 key and the 3 keys are pressed simultaneously, the Police Emergency alarm is activated. This alarm operates exactly the

Pagina 13 - OmniPro II Maintenance

Copyright © 2001-2006 Home Automation, Inc. All Rights Reserved

Pagina 14 - SECURITY SYSTEM OPERATION

Trouble Indications The OmniPro II constantly monitors the alarm zones and several internal matters and will alert you if it detects trouble. The pa

Pagina 15 - Using Shortcut Keys

Manager Code The Manager codes can arm/disarm the security system in assigned areas, during assigned times. The Manager code can access functions th

Pagina 16 - Bypassing Zones

If the ' 0 ' (ALL) key had been selected, the display will show: DISARM ALL AREAS ENTER CODE: #=AREA As the four-digit code

Pagina 17

Testing Your System HAI recommends testing your system on a weekly basis to ensure that you are fully protected. 1. Notify your Central Station tha

Pagina 18 - Emergency Keys

CONTROL Control Commands The control features of the OmniPro II make it easy and convenient to control almost any light or appliance from the consol

Pagina 19 - Alarm Cancel

When set to UPB, the OmniPro II controller can: ¾ Send commands (on, off, bright, dim and level) to individual switches and modules ¾ Receive comma

Pagina 20 - Trouble Indications

When “Status Tracking” is enabled (this is the default setting), OmniPro II keeps track of the exact status of each unit even when a lighting scene is

Pagina 21

A Zone is any individual RadioRA Switch or Dimmer. A RadioRA System has a maximum of 32 Lighting Zones. Zone Numbers can be used to identify any indi

Pagina 22 - GOTO Area

Unit Numbers OmniPro II systems have 511 total Unit Numbers. They consist of HLC, UPB, CentraLite, RadioRA, ALC, Compose, and X-10 module unit numbe

Pagina 23 - Testing Your System

Scrolling Through Names The OmniPro II stores names for Units, Zones, Buttons, Codes, Temperatures, and Messages so that you don't have to reme

Pagina 24 - CONTROL

Contents INTRODUCTION...

Pagina 25

Each lighting scene can also be set or easily changed using the pushbuttons on the HAI UPB™ 6-Button Room Controller, as follows: Step Operation 1 Pr

Pagina 26 - About Lutron RadioRA

¾ Press 4 (LVL) to set the desired lighting level of the selected unit (0%-100%). ¾ 5 (RMP) does not affect CentraLite units. ¾ Press 9 (TIM) to ti

Pagina 27

Ramp Command (ALC) When ALC Switch Modules are being used, it is possible to ramp the lighting level of an ALC Dimmer Switch to a new level at a sele

Pagina 28 - Unit Numbers

Timed Commands The timed commands allow a units to be turned on or off for a specified period of time. The unit may be turned On for 1-99 (minutes o

Pagina 29 - Controlling Units

Controlling Outputs The OmniPro II has eight outputs that can be used to switch relays. Outputs 1-8 are controlled as Unit Numbers 385-392, respecti

Pagina 30

NOTE: The All Off function can be changed, if desired - See Set Up Misc, All On And All Off. Leviton Scene Control OmniPro II supports Leviton Scene

Pagina 31

Scene Off Command Once the Scenes have been sent, press the 0 (OFF) key to command the four units in that Scene to turn off. Notes: 1. When sendi

Pagina 32

Executing Phantom Buttons OmniPro II can turn on and turn off each of the 17 possible Phantom Buttons. Phantom Buttons must be pre-programmed into t

Pagina 33 - Internal Flags

Buttons A powerful feature of the OmniPro II is the ability to program Buttons. A Button (also known as macro) is a number on the keypad that is pro

Pagina 34 - All On / Off

HAI RC-Series Thermostats The following control actions are allowed for HAI Communicating Thermostats: • Set heating setpoints • Set cooling setp

Pagina 36

The fan control on a thermostat may be switched between on and auto by selecting 4 (FAN) from the temperature menu: Upstairs FAN 0=AUTO 1=ON

Pagina 37

The following control actions are allowed on PESMs: • Turn Energy Saver On and Off • Turn Energy Saver On and Off for a specified time • Set heat

Pagina 38 - Temperature Control

Downstairs 0=OFF 1=ON 2=HEAT ↓ Downstairs 3=COOL 9=TIME #=STAT ↑ ENTER TIME MINUTES (1-99) #=H/M/S Downst

Pagina 39 - HAI RC-Series Thermostats

Upstairs 2=LOW 3=HIGH #=STAT For negative temperatures (-1o to -40o), press the ' # ' key prior to entering the temperature to

Pagina 40

Status The Status function is used to display the status of various items in the system. To enter the status menu, from the top-level display or the

Pagina 41

Press 1 (CTRL) to view the current status of each unit and to configure the HLC device that is assigned for each unit. The console will display:

Pagina 42

2 = ZONE The Zone Status menu allows you to view and scroll through the status of each zone input. To enter the Zone menu, from the Status menu, pr

Pagina 43 - Humidity

The next series of displays shows the current analog reading for each security zone input. The displays show the readings for zones 1-176. 1=

Pagina 44 - 1 = CTRL (CONTROL UNITS)

Event Log The Event Log records the 250 most recent significant security system Events (happenings) and trouble conditions in the system. When a new

Pagina 45

Messages The Message menu is used to play and record the memo message and to quickly clear all text messages. The memo message is an eight-second vo

Pagina 46

Humidity...

Pagina 47 - 6= ENERGY (ENERGY COST)

Show Message The 1 (SHOW) key allows you to display the selected text message(s) on the console's top-level display. This can be a helpful re

Pagina 48 - Event Log

Send Message (Pro-Link) The 6 (SEND) key allows you to send any of the text messages through the Pro-Link serial port. You are first prompted to spe

Pagina 49 - Messages

TELEPHONE CONTROL Telephone Interface Your OmniPro II is equipped with a built-in telephone response feature that allows you to control and access t

Pagina 50

Phone Access Denied - Remote Lockout The OmniPro II has a remote lockout feature to discourage youngsters (and adults who act that way) from trying

Pagina 51

1 - Control Press 1 from the MAIN MENU to get to the CONTROL menu. If voice descriptions have been programmed, after a three-second delay, the syste

Pagina 52 - TELEPHONE CONTROL

Press the temperature zone you wish to control, then press #. Press the ' 0 ' key to select all HAI Thermostats. This is a simple way to b

Pagina 53 - Main Menu

8 - Message This command allows you to record and verify the voice memo message, allows you to record and play custom messages (phrases), and allows

Pagina 54

To play one of the custom phrases, press the 6 key. " PLAY PHRASE: ENTER PHRASE NUMBER, THEN POUND." Press the phrase number (1-60) you

Pagina 55 - 7 - Events

Emergency Dial-Out Emergency dial out consists of two distinct parts: the "digital dialer" and the "voice dialer." Digital Dial

Pagina 56 - 8 - Message

After it has dialed the last number in the dial order, the OmniPro II stops dialing and reconnects the in-house phones. What You Hear - If Your OmniP

Pagina 58 - Voice Dialer

Built-In Ethernet Port The built-in Ethernet port (J6) allows a device to connect to the OmniPro II controller via a network (i.e. Ethernet, Internet

Pagina 59 - PC Access

192.168.0.101192.168.0.50192.168.0.51HAI OmniPro IIControllerHub orRouterComputerComputer To connect to an OmniPro II controller on a local networ

Pagina 60

To connect to an OmniPro II controller on a local network using HAI PC Access, under Configure >> Network enter the controller’s IP ad

Pagina 61 - Local Network

SETUP Configuration and Advanced Control Programming (ACP) The Setup menu is used to configure operating parameters, program your system to do its a

Pagina 62 - Local / Wide Area Network

The display will show all areas that have been enabled for that user. After the area(s) is/are selected, press the ' # ' key. CODE 2 AR

Pagina 63 - Set Up Codes

Advanced Control Programming (ACP) Your OmniPro II can be programmed to do automated control and security functions on a time schedule or in response

Pagina 64 - Set Up Time

Menu 1 - Programs for a particular control unit number Menu 2 - All Security related programs Menu 3 - Programs for a particular macro button Menu

Pagina 65

The arrow keys are used to scroll through the programs. Pressing the ' # ' key while a particular program is displayed will allow that prog

Pagina 66

Edit Programs When Selecting the 1 (WHEN) key, from the Edit Program menu, allows the time or button/event that activates the program to be changed.

Pagina 67 - Edit Programs

Button and Event Programs Selecting 2 (BUTTON), from the "Edit When" menu, sets up a program to be activated when a macro button is execute

Pagina 69 - Button and Event Programs

Corresponding Switch Table Switch OmniPro II UPB 6-Button Keypad UPB 8-Button Keypad RadioRA Master Control ALC 4-Button 1 2 On Button 1 or E

Pagina 70 - Corresponding Switch Table

AREA: ENTER AREA 0=ALL ↓ The area number should be entered followed by the ' # ' key, or the arrow keys may be used to sc

Pagina 71

Alarm Event Buttons Pressing the 5 (ALARM) key allows you to specify an event button activated upon the occurrence of an alarm. You are first pro

Pagina 72 - ANY TYPE ↓

The arrow keys are used to select from a list of event buttons: • WHEN ENERGY LO • WHEN ENERGY MID • WHEN ENERGY HI • WHEN ENERGY CRIT • WHEN PH

Pagina 73

Edit Program Command Selecting 2 (CMD), from the Edit Program menu, allows the commanded action for the program to be specified. The following m

Pagina 74 - Edit Program Command

Unit Toggle Command Using HAI PC Access Software, you can create programs to toggle any unit (1-511) from its current state to the opposite state.

Pagina 75

Program Video Commands* This program command is used to display video automatically on an OmniTouch with Video touchscreen when an event occurs. You

Pagina 76

Edit Program Condition Selecting the 3 (&COND) key, from the Edit Program menu, allows the condition for the program to be specified. The condit

Pagina 77 - Edit Program Condition

The zone will be displayed and you will be prompted for the state of the zone: IF Front Door: 0=SECURE 1=NOT RDY Program Time Clock Cond

Pagina 78 - SELECT CONDITION:

Set Up Dial The Set Up Dial menu is used to configure all of the telephone related items for the OmniPro II. To enter the Set Up Dial menu, from the

Pagina 80

Dial Out Number 1 Dial Out Number 1 is one of the 8 numbers that are stored in the system. In the event of an alarm, these numbers are dialed in the

Pagina 81 - Set Up Arming

Set Up Arming To configure different arming and disarming options, from the Setup menu, press the 5 (ARM) key. Entry Delay The Entry Delay is the t

Pagina 82 - Set up Miscellaneous

Enable Quick Arm The Quick Arm feature allows the security system to be armed by pressing the desired mode key twice instead of having to enter your

Pagina 83

Enable Freeze Alarm If there are one or more Thermostat or PESM in a system, they can also be used to detect a freeze condition - See Freeze Alarm.

Pagina 84

House Codes 1-16 All On This feature allows you to choose if House Code 1-16 will respond to the “All On” command. Press the 0 key to select No and

Pagina 85

Latitude, Longitude, and Time Zone The system automatically calculates the time of sunrise and sunset each day. Sunrise/sunset can be specified as t

Pagina 86 - ↓), scroll to the

DST START WEEKEND: FIRST SUNDAY #=CHNG  DST END MONTH: 10 1-12 0=DISABLE  DST END WEEKEND:

Pagina 87 - Set Up Names

Encryption Key Encryption and decryption of data between the OmniPro II controller and the connected device is based on the Advanced Encryption Sta

Pagina 88 - Set Up Address

Set Up Voice The OmniPro II can be set up to speak descriptive names such as "FRONT DOOR" for control zones, units, buttons, codes, tempera

Pagina 89 - FIRE ESCAPE PLANNING

UNDERWRITER'S LABORATORIES REQUIREMENTS For a complete list of requirements and restrictions when installing the OmniPro II panel in a UL Liste

Pagina 90

INTRODUCTION Thank you for purchasing your new OmniPro II automation system. You are about to enjoy a new feeling of security, comfort, convenience

Pagina 91

FEDERAL COMMUNICATION COMMISSION NOTICE: 1. This equipment complies with Part 68 of FCC Rules. On the door, inside of the OmniPro II enclosure, is

Pagina 92

CANADIAN INDUSTRY CANADA NOTICE Notice: The Industry Canada label identifies certified equipment. This certification means that the equipment mee

Pagina 93 - INSTRUCTIONS TO CALLED PARTY

APPENDIX A - DIAL OUT PLANNER Use the following dial-out planner to help you set-up the voice dial-out numbers: OmniPro II Voice Dial-Out Planne

Pagina 94

INSTRUCTIONS TO CALLED PARTY Dear ___________________________________________________________________ I have programmed my OmniPro II Home Automat

Pagina 95

APPENDIX B - TEXT DESCRIPTION CHARACTER CODES CODE CHAR CODE CHAR CODE CHAR CODE CHAR00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18

Pagina 96

Page 87 APPENDIX C - VOICE DESCRIPTION CODES CODE DESCRIPTION 255 (ADDRESS MSG) 58 (BEEP) 254 (MEMO MESSAGE) 29 (PAUSE) 30 (SHORT PAUSE) 26 A. M.

Pagina 97

Page 88 CODE DESCRIPTION CODE 341 FALL 80 FAMILY 81 FAN 342 FATHER’S 343 FAULT 344 FEBRUARY 217 FENCE 5 FIFTEEN 17 FIFTY 218 FILE 345 FILTER 82 FIRE

Pagina 98 - NOTES ON CUSTOM PHRASES

Page 89 CODE DESCRIPTION CODE 444 ONLINE 445 ONLY 233 OPEN 446 OPTION 131 OR 447 OTHER 448 OUT 132 OUTDOOR 133 OUTLET 449 OUTSIDE 450 OVER 234 OVERF

Pagina 99

CODE DESCRIPTION CODE 250 VAULT 536 VCR 537 VIDEO 538 VISITOR 539 VOLUME 540 WAITING 541 WALK 542 WALKWAY 251 WAREHOUSE 543 WARNING 187 WATER 544 WED

Comentarios a estos manuales